Hybrid Environmental Screening Options
Our hybrid DC-DC converters and EMI filters are available in multiple environmental screening grades to satisfy a wide range of requirements.
Our hybrid DC-DC converters and EMI filters are available in multiple environmental screening grades to satisfy a wide range of requirements.
Our hybrid DC-DC converters and EMI filters are available in multiple environmental screening grades to satisfy a wide range of requirements. Environmental screening for the KL1 grade is referenced to the MIL-STD-883 test methods applicable for MIL-PRF-38534 Class K devices, per in-house procedures. Custom environmental screening can be performed to meet specialized needs.
Please contact a sales representative concerning any custom environmental screenings you require.
Screening | MIL-STD-883 Test Method, Condition | Standard 3 | Extended /ES 3 | Engineering model /EM 3,7 | Class H /H | Class K or Class KL1 /K or KL1 3,6 |
---|---|---|---|---|---|---|
Non-Destructive Bond Pull | TM2023 | 2 | 2 | 2 | 2 | |
Internal Visual | TM2010, TM2017, TM2032 (MIL-STD-750, TM2072, TM2073) | |||||
Temperature Cycling | TM1010, Condition C, -65°C to 150°C, Ambient | |||||
TM1010, Condition B, -55°C to 125°C, Ambient | ||||||
Constant Acceleration | TM2001, 3000g, Y1 Direction | |||||
TM2001, 500g, Y1 Direction | ||||||
PIND4 | TM2020, Condition A | |||||
Pre Burn-In Electrical | 100% at 25°C | |||||
Burn-In | TM1015, 320 hrs +125°C, Case Typ | |||||
TM1015, 160 hrs +125°C, Case Typ | ||||||
TM1015, 96 hrs +125°C, Case Typ | ||||||
TM1015, 24 hrs +125°C, Case Typ | ||||||
Final Electrical | MIL-PRF-38534, Group A, Subgroups 1-6 -55°C , 25°C, 125°C 1 | |||||
MIL-PRF-38534, Group A, Subgroups 1 and 4, 25°C | ||||||
Hermeticity | TM1014, Fine Leak, Condition A2 or B1 | |||||
TM1014, Gross Leak, Condition C1 or B2 | ||||||
Gross Leak, Dip (No Bomb), Visual Verification | ||||||
Radiography5 | TM2012 | |||||
External Visual | TM2009 |
Notes:
- 100% R&R testing with all test data included in product shipment.
- Not required per MIL-PRF-38534. Test is performed for additional product quality assurance.
- Non-QML products may not meet all requirements of MIL-PRF-38534.
- PIND test Certificate of Compliance included in product shipment.
- Radiographic test Certificate of Compliance and film(s) or data CD included in product shipment.
- -KL1 products are identical in every way with Class K products in compliance with MIL-PRF-38534 revision L and later revisions except they contain elements evaluated to the requirements of MIL-PRF-38534 revision K and previous revisions. These devices are not marked with an SMD number or MIL-PRF-38534 certification mark and are marked with -KL1 screening code in place of -K.
- Engineering models utilize only the screening specified and are not considered compliant for flight use.

Here To Help
VPT is dedicated to delivering exceptional customer service and our sales team is ready to assist you in powering your next critical mission today.